Inside the two geysers
A typical day once both geysers have settled into a repeating daily pattern. Colour shows the temperature of each layer of water (hot water rises, and cold mains water comes in at the bottom). Press play, or drag the time slider.
Hot water leaving the geyser
Temperature at the top outlet. Grey columns are hot-water draws. The tinted band shows when Geyser B's timer allows power. The dashed line is the air around the geyser.
Electricity used through the day
Running total of electricity over the settled day. The gap at midnight is the daily saving (or extra cost).
When each element is switched on
What it costs, and when
On a time-of-use tariff the same kWh costs different amounts at different times. Top: your tariff's timetable, with when each geyser's element is on. Below: what each hour costs. Pick the tariff in Settings → Electricity price.
Compare every municipal tariff we researched (2026/27)
Where the electricity goes
kWh per day. Energy in equals hot water used, plus hot water left to cool in the pipes, plus heat leaking through the tank walls.
Fair-fight checks
The comparison only counts if Geyser B is at least as hot as Geyser A when every shower starts.
How early must the timer switch on?
Geyser B's daily electricity for different lead times, against Geyser A. Lead times in the hatched zone are too short: B would be colder than A when a shower starts, so that comparison isn't fair. The more lead time you give B, the closer it gets to just being on all the time.
How much energy does the water hold?
Every constant and variable in the model
The values in use right now, with the formula or source behind each. Items marked ≈ are estimates where sources disagree.